VERSION 1 ########################################################## # __ __ __ __ __ # # .--------|__|--| |__| .-----.--.--|__|--| |-----. # # | | | _ | |__| _ | | | | _ | -__| # # |__|__|__|__|_____|__|__|___ |_____|__|_____|_____| # # |_____| # # # ########################################################## # Generated on 2026-04-08 by https://midi.guide , the open, # 'comprehensive' dataset of all MIDI CCs and NRPNs. # Contributions welcome! # Supports all alphanumeric ASCII, and ' ', '_', '-', '+' - can also be NULL TRACKNAME JD-08 # Can be POLY, DRUM, MPE, or NULL TYPE NULL # Can be A, B, C, D, USBD, USBH, CVGx (x between 1&4), CVx, Gx, or NULL OUTPORT NULL # Can be x (between 1-16), or NULL -- this is ignored if output port is not MIDI OUTCHAN NULL # Can be NONE, ALLACTIVE, A, B, USBH, USBD, CVG, or NULL INPORT NULL # Can be x (between 1-16), ALL, or NULL. This definition will be ignored if INPORT is NONE, ALLACTIVE or CVG INCHAN NULL # This defines the default 'MAX RATE' for automation lanes. # Can be NULL, 192, 96, 64, 48, 32, 24, 16, 12, 8, 6, 4, 3, 2, 1 MAXRATE NULL # DRUMLANES # Syntax: ROW:TRIG:CHAN:NOTENUMBER NAME # ROW must be between 1 and 8 # TRIG can be between 0 and 127, or NULL # CHAN can be a number between 1 and 16, Gx, CVx, CVGx (x between 1 and 4), or NULL # NOTENUMBER can be between 0 and 127, or NULL # NAME supports all alphanumeric ASCII, and ' ', '_', '-', '+' - can also be NULL # Please note this section will be discarded for tracks which are not DRUM tracks [DRUMLANES] [/DRUMLANES] # PC # Syntax: NUMBER NAME # number must be either: # - A number (for simple PC) # - Three numbers, delimited by ':', which represent PC:MSB:LSB. You can put 'NULL' to not set the MSB/LSB. # PC must be between 1...128 # MSB/LSB must be between 0...127 [PC] [/PC] # CC # Syntax: CC_NUMBER NAME or CC_NUMBER:DEFAULT=xx NAME # DEFAULT_VALUE must be a valid number between 0 and 127 [CC] 12 FX B level 94 FX B delay center level 95 FX B delay right level 93 FX B chorus level 92 FX B delay left level 91 FX B reverb level 13 FX B reverb time 64 Hold pedal 5 Portamento time 1 Modulation wheel 117 Portamento 118 Portamento mode 116 Legato 66 Sostenuto pedal 49 Bender range down 41 Bender range up 11 Expression 7 Part level 14 LFO 1 rate 17 LFO 1 offset 16 LFO 1 fade 15 LFO 1 delay 18 LFO 1 key trigger 19 LFO 1 waveform 96 LFO 1 rate rate sync 22 LFO 2 fade 20 LFO 2 rate 97 LFO 2 rate rate sync 25 LFO 2 key trigger 24 LFO 2 offset 23 LFO 2 waveform 21 LFO 2 delay 29 Pitch envelope L1 27 Pitch envelope L0 26 Pitch envelope time key follow 31 Pitch envelope T3 30 Pitch envelope T2 28 Pitch envelope T1 35 Pitch envelope L2 58 Amp envelope L1 55 Amp envelope time key follow 60 Amp envelope L2 57 Amp envelope T1 59 Amp envelope T2 61 Amp envelope T3 63 Amp envelope T4 62 Amp envelope sustain level 104 TVA bias point 105 TVA bias level 106 TVA bias direction 103 TVA level 107 TVA LFO select 108 TVA LFO depth 51 Filter envelope L2 53 Filter envelope sustain level 48 Filter envelope L1 46 Filter envelope time key follow 54 Filter envelope T4 52 Filter envelope T3 50 Filter envelope T2 47 Filter envelope T1 56 Filter envelope L4 3 TVF cutoff 102 TVF LFO depth 90 TVF LFO select 89 TVF key follow 87 TVF envelope depth 86 TVF filter mode 9 TVF resonance 110 Level 119 Unison 115 Solo 112 Active 111 Layer 79 Pitch coarse 72 Waveform 85 WG LFO 2 depth 83 WG LFO 1 depth 82 Pitch key follow 81 Pitch random 80 Pitch fine [/CC] # CC Pair # Syntax: CC_MSB:CC_LSB NAME or CC_MSB:CC_LSB:DEFAULT=xx NAME # DEFAULT_VALUE must be a valid number between 0 and 16383 [CC_PAIR] [/CC_PAIR] # NRPN # Syntax: "MSB:LSB:DEPTH NAME" or "MSB:LSB:DEPTH:DEFAULT=xx NAME" # Lsb & msb should be between 0 and 127 # Note: LSB can be over 127 ONLY if MSB is 0 or omitted # e.g. '0:1026:7 FOO', or ':2000:7 BAR' # the examples above would be equivalent to '8:2:7 FOO' and '15:80:7 BAR' respectively # DEPTH can be 7 or 14 # For NRPN: DEFAULT_VALUE must be a valid number, either between 0 and 127 (for 7 bit NRPNs) or between 0 and 16383 (for 14bit NRPNs) [NRPN] [/NRPN] # ASSIGN # Syntax: POT_NUMBER TYPE:VALUE or POT_NUMBER TYPE:VALUE DEFAULT=DEFAULT_VALUE # POT_NUMBER must be between 1 and 8 # TYPE can be "CC", "PB" (pitchbend), "AT" (aftertouch), "CV", "NRPN", or "NULL" (this won't assign the pot). # Non explicitly-defined pots will be considered "NULL" # VALUE VALIDATION #### For CC: Value must be a valid number between 0 and 119 #### For PB and AT, any text after the TYPE will be ignored #### For CV, value must be between 1 and 4 #### For NRPN, value must be MSB:LSB:DEPTH, with both lsb & msb bebtween 0 and 127, and DEPTH being either 7 or 14 # DEFAULT VALUE #### For CC: DEFAULT_VALUE must be a valid number between 0 and 127 #### For PB: DEFAULT_VALUE must be a valid number between 0 and 16383 #### For NRPN: DEFAULT_VALUE must be a valid number, either between 0 and 127 (for 7 bit NRPNs) or between 0 and 16383 (for 14bit NRPNs) #### For CV: DEFAULT_VALUE must be either a valid number between 0 and 65535, or a voltage between -5V and 5V, e.g. "-4.25V" or "1.7V" #### Please note default value will be ignored for PB and AT messages. [ASSIGN] [/ASSIGN] # AUTOMATION # Syntax: TYPE:VALUE # TYPE can be "CC", "PB" (pitchbend), "AT" (aftertouch), "CV", or "NRPN" # VALUE VALIDATION #### For CC: Value must be a valid number between 0 and 119 #### For PB and AT, any text after the TYPE will be ignored #### For CV, value must be between 1 and 4 #### For NRPN, value must be MSB:LSB:DEPTH, with both lsb & msb bebtween 0 and 127, and DEPTH being either 7 or 14 # NOTE: You are limited to 64 automation lanes [AUTOMATION] [/AUTOMATION] # This section will be readable from Hapax. [COMMENT] [/COMMENT]