VERSION 1 ########################################################## # __ __ __ __ __ # # .--------|__|--| |__| .-----.--.--|__|--| |-----. # # | | | _ | |__| _ | | | | _ | -__| # # |__|__|__|__|_____|__|__|___ |_____|__|_____|_____| # # |_____| # # # ########################################################## # Generated on 2026-04-08 by https://midi.guide , the open, # 'comprehensive' dataset of all MIDI CCs and NRPNs. # Contributions welcome! # Supports all alphanumeric ASCII, and ' ', '_', '-', '+' - can also be NULL TRACKNAME Leviasynth # Can be POLY, DRUM, MPE, or NULL TYPE NULL # Can be A, B, C, D, USBD, USBH, CVGx (x between 1&4), CVx, Gx, or NULL OUTPORT NULL # Can be x (between 1-16), or NULL -- this is ignored if output port is not MIDI OUTCHAN NULL # Can be NONE, ALLACTIVE, A, B, USBH, USBD, CVG, or NULL INPORT NULL # Can be x (between 1-16), ALL, or NULL. This definition will be ignored if INPORT is NONE, ALLACTIVE or CVG INCHAN NULL # This defines the default 'MAX RATE' for automation lanes. # Can be NULL, 192, 96, 64, 48, 32, 24, 16, 12, 8, 6, 4, 3, 2, 1 MAXRATE NULL # DRUMLANES # Syntax: ROW:TRIG:CHAN:NOTENUMBER NAME # ROW must be between 1 and 8 # TRIG can be between 0 and 127, or NULL # CHAN can be a number between 1 and 16, Gx, CVx, CVGx (x between 1 and 4), or NULL # NOTENUMBER can be between 0 and 127, or NULL # NAME supports all alphanumeric ASCII, and ' ', '_', '-', '+' - can also be NULL # Please note this section will be discarded for tracks which are not DRUM tracks [DRUMLANES] [/DRUMLANES] # PC # Syntax: NUMBER NAME # number must be either: # - A number (for simple PC) # - Three numbers, delimited by ':', which represent PC:MSB:LSB. You can put 'NULL' to not set the MSB/LSB. # PC must be between 1...128 # MSB/LSB must be between 0...127 [PC] [/PC] # CC # Syntax: CC_NUMBER NAME or CC_NUMBER:DEFAULT=xx NAME # DEFAULT_VALUE must be a valid number between 0 and 127 [CC] 74 Cutoff 57 Pre-drive 58 Keytrack 59 LFO 2 amt 60 Velocity ENV 61 ENV 2 amt 71 Resonance 62 Feedback tone 14 Feedback 15 Time 92 Dry wet 63 Wet tone 53 Velocity ENV 52 LFO 1 amt 55 Cutoff 51 Keytrack 56 Resonance 50 Morph 54 ENV 1 amt 84 Release 81 Attack 82 Decay 83 Sustain 85 Attack 86 Decay 87 Sustain 88 Release 97 Release 96 Sustain 90 Decay 89 Attack 105 Release 102 Attack 103 Decay 104 Sustain 106 Attack 107 Decay 109 Release 108 Sustain 123 All notes off 1 Modulation wheel 11 Expression pedal 32 Bank select LSB 64 Sustain pedal 7 Master volume 70 Level 110 Waveform 72 Rate 73 Rate 111 Waveform 4 Level 75 Level 76 Rate 112 Waveform 77 Level 78 Rate 113 Waveform 80 Rate 114 Waveform 79 Level 17 Macro 2 value 19 Macro 4 value 20 Macro 5 value 21 Macro 6 value 22 Macro 7 value 23 Macro 8 value 18 Macro 3 value 16 Macro 1 value 8 Balance 24 Initial level 33 Pitch 42 Feedback 43 Feedback 34 Pitch 25 Initial level 26 Initial level 35 Pitch 44 Feedback 45 Feedback 27 Initial level 36 Pitch 37 Pitch 28 Initial level 46 Feedback 39 Pitch 47 Feedback 29 Initial level 30 Initial level 48 Feedback 40 Pitch 41 Pitch 49 Feedback 31 Initial level 94 Dry wet 68 Param1 69 Param2 12 Param1 93 Dry wet 13 Param2 91 Dry wet 67 Tone 66 Time 3 LFO 3 amt 2 VCA level 9 Polyphony 65 Glide toggle 95 Detune 5 Glide time 10 Density [/CC] # CC Pair # Syntax: CC_MSB:CC_LSB NAME or CC_MSB:CC_LSB:DEFAULT=xx NAME # DEFAULT_VALUE must be a valid number between 0 and 16383 [CC_PAIR] [/CC_PAIR] # NRPN # Syntax: "MSB:LSB:DEPTH NAME" or "MSB:LSB:DEPTH:DEFAULT=xx NAME" # Lsb & msb should be between 0 and 127 # Note: LSB can be over 127 ONLY if MSB is 0 or omitted # e.g. '0:1026:7 FOO', or ':2000:7 BAR' # the examples above would be equivalent to '8:2:7 FOO' and '15:80:7 BAR' respectively # DEPTH can be 7 or 14 # For NRPN: DEFAULT_VALUE must be a valid number, either between 0 and 127 (for 7 bit NRPNs) or between 0 and 16383 (for 14bit NRPNs) [NRPN] [/NRPN] # ASSIGN # Syntax: POT_NUMBER TYPE:VALUE or POT_NUMBER TYPE:VALUE DEFAULT=DEFAULT_VALUE # POT_NUMBER must be between 1 and 8 # TYPE can be "CC", "PB" (pitchbend), "AT" (aftertouch), "CV", "NRPN", or "NULL" (this won't assign the pot). # Non explicitly-defined pots will be considered "NULL" # VALUE VALIDATION #### For CC: Value must be a valid number between 0 and 119 #### For PB and AT, any text after the TYPE will be ignored #### For CV, value must be between 1 and 4 #### For NRPN, value must be MSB:LSB:DEPTH, with both lsb & msb bebtween 0 and 127, and DEPTH being either 7 or 14 # DEFAULT VALUE #### For CC: DEFAULT_VALUE must be a valid number between 0 and 127 #### For PB: DEFAULT_VALUE must be a valid number between 0 and 16383 #### For NRPN: DEFAULT_VALUE must be a valid number, either between 0 and 127 (for 7 bit NRPNs) or between 0 and 16383 (for 14bit NRPNs) #### For CV: DEFAULT_VALUE must be either a valid number between 0 and 65535, or a voltage between -5V and 5V, e.g. "-4.25V" or "1.7V" #### Please note default value will be ignored for PB and AT messages. [ASSIGN] [/ASSIGN] # AUTOMATION # Syntax: TYPE:VALUE # TYPE can be "CC", "PB" (pitchbend), "AT" (aftertouch), "CV", or "NRPN" # VALUE VALIDATION #### For CC: Value must be a valid number between 0 and 119 #### For PB and AT, any text after the TYPE will be ignored #### For CV, value must be between 1 and 4 #### For NRPN, value must be MSB:LSB:DEPTH, with both lsb & msb bebtween 0 and 127, and DEPTH being either 7 or 14 # NOTE: You are limited to 64 automation lanes [AUTOMATION] [/AUTOMATION] # This section will be readable from Hapax. [COMMENT] [/COMMENT]